I-Line II Low Voltage Busway trunking system

Busbar trunking for power distribution up to 6300A

  • Comprehensive and authorized safety is ensured by full certifications
  • Easy and universal installation
  • Low voltage drop due to large cross section and good contact
  • Stable and long operation period
  • Save in the event of fire
  • Easy maintenance
Features
  • All ratings and PIU fully comply with IEC61439, and obtained the KEMA KEUR/ASTA DIAMOND. Test category includes:
    • Electrical performance
    • Resistance to harsh environment
    • Fire resistance
    • Mechanical strength
  • Sandwich structure busway Compact size, totally enclosed housing
    • Universal installation, free of orientation and mounting position
    • No “Chimney” effect
    • Less space required
    • Improved system ventilation
  • Conductor
    • 99.97% purity of copper conductor with full length silver plated >or silver-plated Bimetal cladding on aluminum conductor.
    • Large cross section
  • I-Line II joint pak
    • VISI-TITE Bolt with double head design, to ensure proper torque is achieved
    • Single bolt connection
    • Belleville washer
    • Double surface contact to busbar
    • Adjustable range ±6mm
  • Insulation
    • Two layers surrounding each busbar, 4 layers between phases
    • Class B vendor certified polyester film
    • Halogen free
Range I-LINE II Copper busway I-LINE II Copper contact busway
Degree of protection IP40 / 41 / 54 / 65 / 66 IP40 / 41 / 54 / 65 / 66
Polarity 3L + N+PE / 3L+ PE; 3L + N+PE / 3L+ PE;
Rating 630 – 6300A 800 – 6300A
Tap-off intervals 610mm/1220mm 610mm/1220mm
Standard lengths 10 Feet 10 Feet
Finish ANSI 49 ANSI 49
Maximum distance between fixing points 10Ft 10Ft

 

Run section ■Rating: 12 ratings are available, from
630A to 6300A
■Standard length: 10 feet, 6 feet, 4 feet
■None-standard length: minimum
length 406 mm
Plug-in unit ■All I-LINE plug-in units are compatible
with I-LINE II busbar trunking system
■Category: plug-in unit with MCCB,
□Plug-in unit with Schneider Electric
MCCB, ampere rating from 15A to 1000A
Elbow fitting ■Standard elbow
□Flatwise elbow
□Edgewise elbow
■Non-standard elbow:
□Double elbow
□Offset elbow
□Elbow plus flanged end
□Elbow in special angle
□Elbow in special length
Connection fitting ■ Supply connections allow the busbar
trunking to be connected to the
switchboard’s busbar or to the
transformer.
□ Flanged end
□ Qwik Flanged end
■ Cable connection, transport current
between cable and busbar trunking.
□ End cable tap box
Fixing supports ■ Vertical support
□ Fix hanger
□ Spring hanger
■ Horizontal support
□ Flatwise hanger
□ Edgewise hanger
□ Center cable tap box